LCD Display: |
3 digits 1000
counts In an RF Field of 3V/m, total accuracy = Specified accuracy + 45d.
Performance above 3V/m is not specified |
Update Rate: |
5 per second nominal |
|
|
|
|
|
Operating Temperature: |
-10ºC ~ 55ºC (14ºF ~ 131ºF) |
|
|
|
|
|
Relative Humidity: |
Maximum relative humidity 80% for
temperature up to 31ºC (87ºF) decreasing linearly to 50% relative humidity at
55ºC (131ºF) |
Altitude: |
Operating below 2000m |
|
|
|
|
|
Storage Temperature: |
-20ºC ~60ºC (-4ºF ~ 140ºF), < 80%
R.H. (with battery removed) |
|
|
Temperature C oefficient: |
Nominal 0.15 x (specified accuracy)/
ºC @ (-10ºC ~ 18ºC or 28ºC ~ 55ºC), or otherwise specified |
Sensing: |
Average sensing |
|
|
|
|
|
|
Type of Protection: |
IP65 |
|
|
|
|
|
|
|
Pollution Degree: |
2 |
|
|
|
|
|
|
|
Safety: |
Meets EN61010-1 and IEC61010-1 2nd
Edition (2001) |
|
|
|
Measurement Category: |
CAT III 1000V & CAT IV 600V AC
& DC |
|
|
|
|
Transient Protection: |
8kV lightning surge (1.2/50µs) |
|
|
|
|
|
Overload Protection: |
1000VDC & VAC rms |
|
|
|
|
|
Low Battery: |
Below approx. 2.4V |
|
|
|
|
|
|
Power Supply: |
Standard 1.5V AAA Size (NEDA 24G or
IEC R03) battery X 2; or 1.5V AAA Size (NEDA 24A or IEC LR03) alkaline
battery X 2 |
Power Consumption (typical): |
3mA at Power-on ready; 30mA at
1000VAC full LED indication. 75mA at 1000VAC with shaker ON |
APO Consumption (typical): |
10µA |
|
|
|
|
|
|
|
Special Features: |
High Input Impedance, Indicator
Self-Test, Auto-Hold, Overload-Alert Warning, EF-Detection, |
Special Features: |
Auto Display Backlit, AC-Detection
Shaker, Bi-Color LED Hazardous Live Warning, and GFCI Leakage Load |
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
Rugged
and easy to use testers for live voltage and continuity
checks. Built in shaker provides the same functionality and feel as
older analog solenoid testers with benefit of full input protection
to CAT IV 600V / CAT III 1000V.
- Super-bright bi-Color LED’s indicates safe and dangerous
voltages (above 55VDC or 30VAC)
- Auto hold feature - LED’s stay illuminated for 10 sec retaining
a reading after the tests are disconnected
- Solenoid tester-like shaker to indicate AC voltage presence
- Automatically turns ON and OFF for easy and quick measurements
- Non-contact voltage detection and GFCI test feature for testing
GFCI receptacles and breakers
- Standard detachable test lead (black) for easy replacement
with optional longer or specialized probe
- Automatically selects AC Voltage, DC Voltage or Continuity
- LED’s indicate 10 levels of AC and DC Voltages::
- Volts (AC) 24, 48, 120, 208, 240, 277, 347, 480, 600, 1000
- Volts (DC) 6, 12, 24, 36, 48, 60, 72, 110, 220, 380
- Auto backlit LCD Digital Display for precise voltage
measurements
- Continuity buzzer and Visual continuity indication (LED)
- Water and dust proof, IP65 design
- Detachable (Black) Test Lead, Screw-on Stationary (Red) Probe, 2
Screw-on 4mm Probe batteries installed and User’s manual
|
|
|
|
|
|
|