DC
Voltage range |
200 mV to 1000 V, 5 ranges,
Best accuracy: ±0.025 %
rdg. ±2 dgt. |
AC
Voltage range |
2000 mV to 700 V, 4 ranges,
Best accuracy: ±0.2 %
rdg. ±100 dgt. , Effective value rectifier |
Frequency
characteristics |
10 to 300 kHz |
at AC
Voltage |
Resistance
range |
200 ohm to 100 M-ohm, 7 ranges,
Best accuracy: ±0.05 %
rdg. ±2 dgt. |
DC
Current range |
None |
AC
Current range |
(Used with clamp-on sensor
range) |
Frequency
characteristics |
(clamp-on sensor
specification) |
at AC
Current |
Frequency
range |
None |
Continuity |
Possible, 50 ohm or less (at
2000 ohm range) |
Diode
check |
Possible (6 V open terminal
voltage) |
Other
functions |
Current measurement (with
clamp), Comparator, external input and output, Save/Load function, AVE,
trigger, RS-232C, GP-IB ( -01 model ) |
Range
switching |
Auto or Manual |
Display |
LED, max. 199999 dgt., max.
999999 dgt. (at Frequency) |
Sampling
rate |
300 times/sec (Fast), 8 to 9
time/sec (Medium), 1 time/sec (Slow) |
Power
supply |
100 to 240 V AC, 50/60 Hz,
(specify when ordering) |
Dimensions,
mass |
215 mm(8.46 in)W × 80 mm(3.15
in)H × 265 mm(10.43 in)D, 2.6 kg (91.7 oz) |
|
TEST LEAD 9170 (1), Power cord