AC
Current (50 Hz-500 Hz) |
Ranges 20 mA, 200 mA, 10 A |
Resolution 10 uA, 100 uA, 10
mA |
Accuracy 20 mA to 200 mA
ranges: ±(2.0 % rdg + 5 dgts) |
10 A range: ±(3.5 % rdg + 5
dgts) |
Input Protection 0.5 A/500 V
& 10 A/600 V fast blow ceramic fuses |
10A Input 10 A for 60 sec
max. followed by a 10 minute cooling period |
Resis tance |
Ranges 200 Ω, 2 kΩ, 200 kΩ,
20 MΩ, 2000 MΩ |
Resolution 0.1 Ω, 1.0 Ω, 100
Ω, 10 kΩ, 1 MΩ |
Accuracy 200 Ω to 200 kΩ
ranges: ±(1.0 % rdg + 4 dgts) |
20 MΩ range: ±(2.0 % rdg + 4
dgts) |
2000 MΩ range: ±(5.0 % rdg +
10 dgts) |
Open Circuit Voltage
(typical) 0.3 VDC (3.0 VDC on 200 Ω, 2000 MΩ range) |
Overload Protection 500
VDC/ACrms |
Capacitance |
Ranges 2 nF , 20 nF, 200 nF,
2.0 uF, 20 uF |
Resolution 1 pF, 10 pF, 100
pF, 1 nF, 10 nF |
Accuracy ±(4 % rdg + 10 dgts) |
Overload Protection Discharge
capacitor before connecting |
Frequency |
Ranges 2 kHz, 20 kHz, 200
kHz, 2 MHz, 20 MHz |
Resolution 1 Hz, 10 Hz, 100
Hz, 1 kHz, 10 kHz |
Accuracy ±(0.1 % rdg + 3
dgts) |
Sensitivity 2.0 Vrms minimum |
Minimum Pulse Width >25 ns |
Duty Cycle Limits >30 %
and <70 % |
Overload Protection 500
VDC/AC rms |
Diode Te st |
Test Current 1.0 mA (typical) |
Resolution 10 mV |
Accuracy ±(1.5 % rdg + 3
dgts) |
Open Circuit Voltage 3.0 VDC
(typical) |
Overload Protection 500
VDC/ACrms |
Continuity |
Audible Indication Less than
100 Ω |
Response Time 100 ms |
Overload Protection 500
VDC/ACrms |
Transis tor hFE |
Range 0 to 1000 |
Base Current Approximately 10
uADC (VCE = 3.0 VDC) |
Logic Te st |
Threshold Logic Hi (2.8 V
+0.8 V) / Logic Lo (0.8 V +0.5 V) |
Indication 40 msec beep at
logic Lo |
Overload Protection 500
VDC/AC rms |
General |
Display 3 1/2 digit, 2000
count LCD |
Polarity Automatic, positive
implied, negative polarity indication |
Overrange OL or -OL is
displayed |
Low Battery Indication The
battery symbol will display when battery voltage drops |
below operating levels |
Measurement Rate 2.5 times
per second |
Auto Power Off Approximately
30 minutes |
Operating Environment 0șC to
50șC at <70 % relative humidity |
Storage Environment -20șC to
60șC at 0 to 80 % relative humidity |
Accuracies Stated accuracy at
23șC +5șC at <75 % relative humidity |
Temperature Coefficient 0.1 x
(specified accuracy) per șC. (șC to 18șC, 28șC to 50șC) |
Power Single standard 9 volt
battery, NEDA 1604, JIS 006P, IEC 6F22 |
Battery Life 150 hours
typical |
Dimensions 165 mm (H) x 78 mm
(W) x 42.5 mm (D) |
Weight Approximately 10.3 oz.
(377 g) with battery and hanger |