Specification : | Model | AMF-500W | AMF-11001 | AMF-11003 | AMF-11005 | AMF-11010 | AMF-31020 | AMF-31030 | AMF-31045 | AMF-31060 | AMF-31110 | Capacity | 500VA | 1KVA | 3KVA | 5KVA | 10KVA | 20KVA | 30KVA | 45KVA | 60KVA | 100KVA | Circuit Type | IGBT / Pulse Width Modulation Type | Input (AC) | Phase | 1 Phase 2W+G | 3W +G (Δ) : 220V(G) or 3W +N+G (Y) : 220V/380V(T) | Voltage | 110(B) or 220V(G) ±15% | 220V(G) ±15% | 220V(G) ±15% or 220V/380V (T) ±15% | Frequency | 50Hz ± 3Hz , 60HZ ±3Hz | Output(AC) | Phase | 1 Phase 2W+G | Voltage | 115V(C) or 220V(G) , 230V(H) Output Voltage ±10% Adjustable | Frequency | 2-Step Output Frequency: 1) 400Hz Fixed, 2) 350Hz~450Hz adjustable (*can comply with customers) | Frequency Stability | ≤ 0.01% | Load Regulation | ≤ ±1% | ≤ ±1.5% | THD(Total Harmonic Distortion) | ≤ 2% | ≤ 3% | Meter /Res | 4Digital Freq. Meter | Res. 0.1Hz | 4Digit Voltage Meter | Res. 0.1V | Digit Ammeter | 0.001A | 0.01A | 4 Digital Ammeter / Res. 0.1A | 5 Digital Ammeter / Res. 0.1A | Over Load | 120% 1hr , 150% 1min , 200%15sec , 25% (duty cycle)
| Protection | Input/Output Breaker; Electronic for fast detection and trip off protection for Over Current , Over Voltage , Over Load , Over Temperature , Short-Circuit and Alarm system | Isolation Resistance | 500Vdc 20MΩ above | Withstand Voltage | 1800Vdc / 5mA / 1min | Cooling System | Air Force Fan | Environment | Ambient Temperature | -20ºC ~ 45ºC | Humidity | 0 ~ 95% (Non-condensing) | Dimension(W*D*H/mm) | 430x520x200 | 430x520x720 | 430x750x990 | 600x970x1240 | 800x1090x1600 | 920x1250x1700 | Net Weight(kg) | 44 | 60 | 73 | 89 | 150 | 280 | 333 | 418 | 571 | 898 |
Model | AMF-33006 | AMF-33010 | AMF-33020 | AMF-33030 | AMF-33045 | AMF-33060 | AMF-33075 | AMF-33100 | AMF-33150 | AMF-33180 | Capacity | 6KVA | 10KVA | 20KVA | 30KVA | 45KVA | 60KVA | 75KVA | 100KVA | 150KVA | 180KVA | Circuit Type | GBT / Pulse Width Modulation Type | Input (AC) | Phase | 3W +G (Δ) : 220V(G) or 3W +N+G (Y) : 220V/380V(T) | Voltage | 3W +G 220V(G) or 3W +N+G ; 220V/380V (T) ±15% | Frequency | 50Hz ± 3Hz , 60HZ ±3Hz | Output(AC) | Phase | 3W +N+G (Y) | Voltage | 200V / 115V (P) Output Voltage ±10% Adjustable | Frequency | 2-Step Output Frequency: 1) 400Hz Fixed, 2) 350Hz~450Hz adjustable (*can comply with customers) | Frequency Stability | ≤ 0.01% | Load Regulation | ≤ ±1% | ≤ ±1.5% | THD(Total Harmonic Distortion) | ≤ 2% | ≤ 3% | Meter /Res | 4Digital Freq. Meter | Res. 0.1Hz | 4Digit Voltage Meter | Res. 0.1V | Digit Ammeter | 4 Digital Ammeter / Res. 0.1A | 5 Digital Ammeter / Res. 0.1A | Phase Shift | Balanced Load / Empty Load : ≤ ± 2º ; 100% Unbalanced Load ≤ ± 4º | Over Load | 120% 1hr , 150% 1min , 200%15sec , 25% (duty cycle) | Protection | Input/Output Breaker; Electronic for fast detection and trip off protection for Over Current , Over Voltage , Over Load , Over Temperature , Short-Circuit and Alarm system | Isolation Resistance | 500Vdc 20MΩ above | Withstand Voltage | 1800Vdc / 5mA / 1min | Cooling System | Air Force Fan | Environment | Ambient Temperature | -20ºC ~ 45ºC | Humidity | 0 ~ 95% (Non-Condensing) | Dimension(W*D*H/mm) | 430x750x990 | 600x970x1240 | 800x1090x1600 | 920x1250x1700 | 2000x1000x2000 | Net Weight(kg) | 150 | 175 | 345 | 385 | 528 | 635 | 700 | 1000 | 1350 | 1800 | 1. For the other voltages, please refer to Form 1 - Input Voltage Form. 2. The dimensions and weights vary with voltage. For detailed information, please consult with our sales rep. 3. The above dimensions and weights are for Free Standing type only. As to the other types (e.g. T=Trailer, B= Bridge Mount, W=Wall Mounted, O=Open Frame), please consult with our sales rep. 4. One year warranty. 5. All specifications are subject to change without prior notice. 6. 36VAC on request, or comply with customer’s specs. 7. “Add on module” of 400Hz Frequency Power Source and 28VDC DC Power Supply on request. |
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
400Hz Solid State Frequency Power Source
◇Small, Light & Space Saving: | Typically, 1/4 size of motor-generator sets of the same power output rating. |
| ◇High Efficiency, Optimum Stability, Superior Heat Dissipation. | ◇Economical Cost of Ownership:- Modular design permits quick and easy replacement.
- High efficiency features reduce operating costs through 25% and upward utility savings compared to motor-generator sets.
- On-site repairs are easily accomplished.
- Motor-generator sets quite often must be removed from location for repairs, resulting in construction charges.
- Solid State design eliminates the need for a concrete pad for mounting.
|
| ◇Low Noise:- Solid State frequency Power Source have no moving mechanical parts generating a loud racket, it can be located close to the equipment they serve.
- Its low audible noise level eliminates the need for expensive sound insulation.
|
| ◇Low Harmonic Distortion:Total harmonic distortion at 3% max. |
| ◇Pure Output Power Quality: | Double Conversion. It provides clean and consistent sine wave output. |
| ◇±10% Output Voltage Adjustable. | ◇Abnormal Protection:Electronic circuits for fast detection and trip off protection for Over current, over voltage, over temperature, short circuit and Alarm system. |
| ◇Strong Overload Capability:120% - 1 hour, 150% - 1 minute, 200% - 15 seconds at 25% duty cycle. |
| ◇Individual Phase Regulation at Output:Excellent voltage regulation under 100% unbalance load. |
| ◇Output Isolation Transformer,capable to sustain CEMF (counter-electromotive force). |
| ◇MIL-STD-704 compliant. | ◇Option:u36VAC input voltage or acc. to customer's specifications. v"Add on module" of Solid State frequency Power Source and 28VDC power supply. |
|
|
|
|
|
|
|
|