Electrical Specifications |
|
Output Ratings: |
|
|
|
Output Voltage |
|
0-20 V |
|
Output Current |
|
0-3 A |
|
Output Power |
|
60 W |
|
Line Regulation: |
|
|
|
Voltage (0.01% of Vmax + 2 mV) |
|
2 mV |
|
Current (0.01% of Imax + 250 µA ) |
|
0.4 ma |
|
Load Regulation: |
|
|
|
Voltage (0.01% of Vmax + 2 mV) |
|
2 mV |
|
Current (0.01% of Imax + 250 µA) |
|
0.4 mA |
|
Output Noise & Ripple: |
|
|
|
Voltage rms |
|
<1 mV |
|
Current rms |
|
<1 mA |
|
Meter Accuracy: |
|
|
|
Voltage (1% of Vmax + 1 count) |
|
0.3 V |
|
Current (1% of Imax + 1 count) |
|
0.04 A |
|
Drift (8 hours): |
|
|
|
Voltage (0.02% of Vmax) |
|
4 mV |
|
Current (0.03% of Imax) |
|
0.9 mA |
|
Temperature coefficient: |
|
|
|
Voltage (0.015% of Vmax/° C) |
|
3 mV |
|
Current (0.02% of Imax/° C) |
|
0.6 mA |
|
Interface Specifications 1,6 |
|
Program Resolution (16-bit): |
|
|
|
Voltage |
|
0.34 mV (+/- 0.15%) |
|
Current |
|
0.05 mA (+/- 0.15%) |
|
OVP |
|
0.34 mV |
|
Program Accuracy: |
|
|
|
Voltage (0.2% + 10 mV) |
|
20 mV |
|
Current (0.3% + 10 mA) |
|
50 mA |
|
OVP (0.5%) + 100 mV) |
|
200 mV |
|
Readback Resolution (16-bit): |
|
|
|
Voltage |
|
0.34 mV |
|
Current |
|
0.05 mA |
|
Readback Accuracy: |
|
|
|
Voltage (0.2% + 20 mV) |
|
10 mV (+/- 0.1%) |
|
Current (0.3% + 20 mA) |
|
50 mA (+/- 0.15%) |
|
|
|
|
|
1. Specifications indicate typical performance at 25° C +/- 5° C, nominal line input of 115 VAC. |
|
2. For input voltage variation over the AC input voltage range, with constant rated load. |
|
3. For 0-100% load variation, with constant nominal line voltage. |
|
4. Maximum drift over 8 hours with constant line, load and temperature, after 30 minutes warm-up. |
|
5. Change in output per ° C change in ambient temperature, with constant line and load.
6. Apply accuracy specifications according to the following voltage program accuracy example: Set a model 15-4 power supply to 10 volts. The expected result will be within the range of 10 volts +/- 20 mV +/- 0.1% of the set voltage of 10 volts. |
|
|
|
General Specifications |
|
Operational AC input voltage |
|
Standard: 115 VAC +/- 10%. 57-63 Hz; Optional: 110/220/230/240 VAC +/-10%, 47-63 Hz |
|
AC Input Current |
|
Single Unit: 1.2 A, Dual Unit: 2.4 A, Triple Unit: 3.6 A, Quad Unit: 4.8 A, at 115 VAC |
|
Voltage Mode Transient Response Time |
|
<100 µs recovery to 0.05% band, +/-50% load change in the range of 25% to 100% of the rated load |
|
Operating Ambient Temperature |
|
0° C to 30° C for full rated output. Above 30° C, derate output linearly to zero at 70° C |
|
Storage Temperature Range |
|
-55° C to 85° C |
|
Humidity Range |
|
0 to 80% HR, non-condensing |
|
Front Panel Voltage and Current Control |
|
10-turn voltage and 1-turn current potentiometers (10-turn current optional) |
|
Front Panel Voltage Control Resolution |
|
0.02% of maximum voltage |
|
AC Input Connector Type |
|
IEC 320 connector |
|
Weight (one unit) |
|
Approximately 7.7 lb (3.5 kg) |
|
Dimensions (H x W x D) |
|
5.2 x 4.2 x 11.7” (132 x 109.2 x 297 mm) |
|
Options |
|
GPIB-XT |
|
GPIB Interface card (16-bit) |
|
RS-232-XT |
|
RS-232 Interface card (16-bit) |
|
APG-XT |
|
Analog programming interface card |
|
M1 110 |
|
110 VAC Input (50/60 Hz) |
|
M2 220 |
|
220 VAC Input (50/60 Hz) |
|
M3 230 |
|
230 VAC Input (50/60 Hz) |
|
M4 240 |
|
240 VAC Input (50/60 Hz) |
|
M11 |
|
10-turn current potentiometer |
|
M13A |
|
Locking knobs for front panel controls |
|
M43 |
|
Switching selectable Input 110 VAC or 220 VAC |
|
RM-XHS |
|
19-inch rack mount kit for up to four XT, XPD or HPD power supplies |
|
Analog Programming |
|
Remote On/Off and Interlock |
|
2-25 VDC high. <0.8 VDC low. User-selectable. |
|
Remote analog Programming Option |
|
0-10 VDC for 0-100% of rated voltage or current ±0.1%, 0-10 kΩ for 0-100% of rated voltage or current ±0.1% |
|
Remote Monitoring |
|
0-10 VDC for 0-100% or rated voltage or current ±0.1% |
|
Over Voltage Protection Trip Range |
|
3 V to full output +10% |
|
Tracking Accuracy |
|
+/- 1% for series operation |
|
Regulatory Approvals |
|
CSA certified to CSA C22.2 No 107.1; Meets USA EMC standard: FCC, part 15B, class A; Meets Canadian EMC standard: ICES-001, Class A (Models up to and including 120V). |
|
Note: Specifications subject to change without notice. |