AC WITHSTANDING | Output-Voltage Range | 0.10kV~ 5.00kV ac | Output-Voltage Resolution | 10V | Output-Voltage Accuracy | ± (1.5% of setting + 2 counts) with no load | Maximum Rated Load | 100 VA (5kV/20mA) | Maximum Rated Current | 20mA (0.5kV < V ≦ 5kV) 5mA (0.1kV ≦ V≦ 0.5kV) | Output-Voltage Waveform | Sine wave | Output-Voltage Frequency | 50 Hz / 60 Hz selectable | Voltage regulation | ± (1.5% + 2 counts) [full load → no load] | Voltmeter Accuracy | ± (1.5% of reading + 2 counts) | Current Measurement Range | 0.01mA~20.0mA | Current Best Resolution | 0.01mA / 0.1mA | Current Measurement Accuracy | ±(2.0% of reading + 5 counts) when HISET < 1.00mA ±(2.0% of reading + 3 counts) when HISET ≧ 1.00mA | Current Judgment Accuracy | ±(3.0% of setting + 5 counts) when HISET < 1.00mA ±(3.0% of setting + 3 counts) when HISET ≧ 1.00mA | Window Comparator Method | Yes | ARC Detect | Yes | RAMP (Ramp-Up Time) | 0.1s fixed | TIMER (Test Time) | OFF, 1s~180s | GND | ON | DC WITHSTANDING | Output-Voltage Range | 0.10kV~ 6.00kV dc | Output-Voltage Resolution | 10V | Output-Voltage Accuracy | ± (1.5% of setting + 2 counts) with no load | Maximum Rated Load | 25W (5kV/5mA) | Maximum Rated Current | 6mA (0.5kV < V ≦ 6kV) 2mA (0.1kV ≦ V≦ 0.5kV) | Voltage regulation | ± (1.5% + 2 counts) [full load → no load] | Voltmeter Accuracy | ± (1.5% of reading + 2 counts) | Current Measurement Range | 0.01mA~6.00mA | Current Best Resolution | 0.01mA | Current Measurement Accuracy | ±(2.0% of reading + 5 counts) when HISET < 1.00mA ±(2.0% of reading + 3 counts) when HISET ≧ 1.00mA | Current Judgment Accuracy | ±(3.0% of setting + 5 counts) when HISET < 1.00mA ±(3.0% of setting + 3 counts) when HISET ≧ 1.00mA | Window Comparator Method | Yes | ARC Detect | Yes | RAMP (Ramp-Up Time) | 0.1s fixed | TIMER (Test Time) | OFF, 1s~180s | GND | ON | INSULATION RESISITANCE | Output-Voltage | 50V, 100V, 250V, 500V, 1000V dc | Output-Voltage Accuracy | ± (3.0% of setting + 1 count) [no load] | | 1MW~ 2000MW | | Test voltage | Measurable Range | Accuracy | | 50V/100V/250V | 1~ 50MW 51~ 2000MW | ±(5% of reading + 2MW) ±(10% of reading + 2MW) | | 500V/1000V | 1~ 500MW 501~ 2000MW | ±(5% of reading + 2MW) ±(10% of reading + 2MW) | Window Comparator Method | Yes | Output Impedance | 600kW | RAMP (Ramp-Up Time) | 0.1s fixed | TIMER (Test Time) | OFF, 1s~180s | GND | OFF (fixed) | TEST MODE* | | ACW, DCW, IR | AUTO | AC-IR, IR-AC, DC-IR, IR-DC | INTERFACE | | Standard | SIGNAL IO | Standard | General | DISPLY | 240 x 48 Ice Blue dot matrix LCD | POWER SOURCE | AC 100V-120V/220V-240V ±10%, 50/60Hz | POWER COMSUMPTION | 400VA max. | DIMENSIONS & WEIGHT | 330(W) x 148(H) x 385(D) mm approx.9kg(Max) |
Quick Start Guide x 1, CD x1(completed user manual) Power cord x 1, Interlock key x 1, Remote terminal male plug x 1, Test lead GHT-114 x 1 Optional AccessoriesGHT-113 High Voltage Test Pistol GHT-205 High Voltage Test Probe GRA-417 RACK Adapter Panel (19”, 4U)
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
※ 100VA AC Test Capacity ※ 240x48 Ice Blue Dot matrix LCD ※ Auto W-I or I-W Mode ※ ARC Detection ※ True RMS Current Measurement ※ Zero Crossing Turn-on Operation ※ Safety INTERLOCK function ※ PWM amplifier to enhance the power efficiency and reliable testing ※ Automatically Switching Input Source for Universal Input Voltage ※ Interface : Remote terminal and Signal I/O
GW Instek launches new economical safety testers, the GPT-9600 Series, which offers an affordable solution for supporting routine tests of major items of the safety standards such as IEC, EN, UL, CSA, GB, JIS and other safety regulations. The GPT-9600 Series is built upon a platform of 100VA AC maximum power output. The GPT-9603 is a 3-in-1 model capable of performing AC withstanding, DC withstanding and insulation resistance tests. The GPT-9612 is capable of performing AC withstanding and insulation resistance tests. The GPT-9602 is capable of performing AC and DC withstanding tests, and GPT-9601 is able to perform AC withstanding test. The GPT-9600 Series is equipped with the high-efficiency PWM amplifier, which is the core of the platform design to impede the influence from the input AC voltage fluctuation and ensure a stable voltage output. Following a tidy and easy-to–use design concept, the GPT-9600 Series renders users an intuitive operation environment by a simple and clear panel layout, a large LCD display and color LED indicators. The switching power supply, used as a universal input source, accommodates the power systems in most countries in the world. The GPT-9600 series, equipped with the same output voltage function as that of all GW Instek Safety Testers, indicates the expected output voltage before high voltage tests are applied. Furthermore, an AUTO mode, including test sequence selections of withstanding-then-insulation or insulation-then-withstanding, is designed for models carrying insulation Resistance test function to reduce the testing time of dual test items. Other functions and features of GPT-9600 include: the zero crossing turn-on operation protects DUT from the impact of surge voltage output, the interlock function safeguards users from the hazardous shock of unintentional touch of the voltage output, a remote output on-off terminal in the front panel and a signal I/O port in the rear panel are provided as the means for remote start/stop control of the safety tester.
|
|
|
|
|
|
|