Electrical Specifications |
|
Output Ratings: |
|
|
|
Output voltage |
|
0 - 75 V |
|
Output current |
|
0 - 2 A |
|
Outputs |
|
2 |
|
Output power |
|
300 W |
|
Operating mode |
|
Constant voltage or constant current with automatic cross-over and indication |
|
Voltage setting |
|
By coarse and fine controls |
|
Current setting |
|
By single logarithmic control |
|
Output impedance |
|
Typically <5mW in constant voltage mode. Typically >50kW in constant current mode. |
|
Line regulation |
|
<0.01% of max. output for a 10% line voltage change |
|
Load regulation |
|
<0.1% of max. output for a 90% load change, <0.1% (in Mode C) |
|
Ripple and noise (20 MHz bandwidth) |
|
Typically <15 mV rms, <10 mV pk-pk, CV Mode |
|
Transient response |
|
<200ms to within 50 mV of set level for 90% load change (Mode A only) |
|
Temperature coefficient |
|
Typically <100ppm/oC |
|
Output protection |
|
Outputs will withstand forward voltages up to 85 V/170 V |
|
Status indication |
|
Output ON lamps. Constant current mode lamps. |
|
Output switch |
|
Electronic. Preset voltage/current displayed with output off. |
|
Output terminals |
|
Special safety terminals on XPH 75-2D. |
|
Meters (main outputs): |
|
|
|
Meter types |
|
Separate 4 digit meters for voltage and current with 14mm (0.56") LED displays. Reading rate 4/sec. |
|
Meter resolution |
|
100 mV, 10 mA |
|
Meter accuracy: |
|
|
|
Voltage |
|
0.3% +/- 1 digit |
|
Current |
|
0.6% +/- 1 digit |
|
Multi-Mode Operation (XPH 75-2 only) |
|
Three modes of operation can be selected via rotary switch: |
|
|
Mode A: |
|
Two independent and isolated outputs (75 V/ 2 A each) |
|
Mode B: |
|
One output of double the current capability (75 V/ 4 A). Unused output is disabled and its displays are blanked. |
|
Mode C: |
|
One output of double the voltage capability (150 V/2 A). Unused output is disabled and its displays are blanked. |
|
General Specifications |
|
Cooling |
|
Convection (Fan assisted for XPH 42-10) |
|
Output terminals: |
|
|
|
Standard type |
|
4mm "binding post" terminals suitable for plugs or wires |
|
Optional (all models) |
|
4mm safety sockets, suitable for shrouded plugs |
|
AC input |
|
110 V to 240 V +/- 10%, 50/60 Hz |
|
Consumption |
|
500 VA |
|
Operating range |
|
5oC to 40oC, 20% to 80% RH |
|
Storage range |
|
-40oC to 70oC |
|
Environmental |
|
Indoor use at altitudes to 2000m, Pollution Degree 2 |
|
Safety |
|
Complies with EN61010-1 |
|
EMC |
|
Complies with EN61326 |
|
Dimensions (HxWxD) |
|
160 x 260x 320mm |
|
Unit weight |
|
9.7 lbs/4.4 kg |
|
Warranty |
|
3 years |
|
Regulatory Approvals |
|
CE-marked units meet: EN61010-1 and EN 61326 |
|
Note: Specifications subject to change without notice. |