Features
TDS3000C Series Oscilloscopes
Performance you need at a price you can afford
With bandwidths up to 500 MHz, the Tektronix TDS3000C Series oscilloscopes provide you with affordable performance in a compact, battery-capable design.
This popular Series, now equipped with USB host port and PC connectivity software, also provides you with familiar operation and simple navigation so you spend less time learning and re-learning how to use your oscilloscope and more time on the task at hand.
Digital Phosphor Oscilloscopes
TDS3000C Series |
Features & Benefits
Key Performance Specifications
-
100 MHz, 300 MHz, and 500 MHz Bandwidth Models
-
2 or 4 Channels
-
Sample Rates up to 5 GS/s Real-time on All Channels
-
10 k Standard Record Length on All Channels
-
3,600 wfms/s Continuous Waveform Capture Rate
-
Suite of Advanced Triggers
Ease of Use Features
-
Front Panel USB Host Port for Easy Storage and Transfer of Measurement Data
-
25 Automatic Measurements
-
FFT Standard
-
Multiple Language User Interface
-
WaveAlert® Automatic Waveform Anomaly Detection
-
TekProbe® Interface Supports Active, Differential and Current Probes for Automatic Scaling and Units
Portable Design
Application Modules for Specialized Analysis
Applications
Performance You Need at a Price You Can Afford
Performance in an Affordable Package
The TDS3000C Series digital phosphor oscilloscopes (DPO) provide you with the performance you need at a price you can afford. Bandwidths range from 100 MHz to 500 MHz, with up to 5 GS/s sample rates for accurate representation of your signal.
DPOs Provide a Greater Level of Insight into Complex Signals
To solve a problem, first you need to see it. The TDS3000C Series combines 3,600 wfms/s continuous waveform capture rate and real-time intensity grading so you can see the problem and solve it.
Fast waveform capture rates on a continuous basis save time by quickly revealing the nature of faults so advanced triggers can be applied to isolate them.
Real-time intensity grading highlights the details about the history of a signal’s activity, making it easier to understand the characteristics of the waveforms you’ve captured. Unlike other comparable oscilloscopes, the history remains even after the acquisition is stopped.
Quickly Debug and Characterize Signals with DRT Sampling Technology and sin(x)/x Interpolation
The TDS3000C Series combines unique digital real-time (DRT) sampling technology with sin(x)/x interpolation to allow you to accurately characterize a wide range of signal types on all channels simultaneously. With the TDS3000C Series there is no change in sampling rate when additional channels are turned on, unlike other comparable oscilloscopes. This sampling technology makes it possible to capture high-frequency information, such as glitches and edge anomalies, that elude other oscilloscopes in its class, while sin(x)/x interpolation ensures precise reconstruction of each waveform.
Look for unintentional circuit noise with the TDS3000C Series’ FFT capability. Custom video triggering allows the TDS3000C Series to trigger on standards such as RS-343 (26.2 kHz scan rate). The TDS3000C Series provides breakthrough test speeds for telecommunications line card testing. The telecom QUICKMENU puts all the commonly used telecom test functions on a single menu.
The TDS3000C Series with the TDS3LIM module is ideal for manufacturing test applications where fast Go/No-Go decisions are required.
Trace and identify ITU-R BT.601 video signals with the TDS3SDI 601 Serial Digital Video Module.
WaveAlert waveform anomaly detection alerts you to any waveform that deviates from the “normal” input such as the glitch on channel 2.
Easy Set-Up and Use
When working under tight deadlines, you need your oscilloscope to be intuitive; you want to minimize time spent learning and re-learning how to use it. The TDS3000C Series oscilloscopes help reduce your learning curve. Simple navigation and dedicated front panel controls get you to where you want to be quickly, so that you spend less time learning and more time on the task at hand.
Simple Documentation and Analysis
The TDS3000C Series comes equipped with a USB host port so you can easily store and transfer measurement information to your PC.
OpenChoice® PC Communication Software allows you to simply pull screen images and waveform data into a stand-alone desktop application or directly into Microsoft Word and Excel.
To complement OpenChoice, National Instruments LabVIEW SignalExpress™ Tektronix Edition Software provides you with extended capabilities including advanced analysis, data logging, remote instrument control and live waveform analysis.
If you prefer not to use a PC for analysis, the TDS3000C Series comes standard with 25 automatic measurements, waveform add, subtract, divide, and multiply math functions, and Fast Fourier Transform (FFT). Unlike other comparable oscilloscopes, the TDS3000C Series math and measurement allows you to use the full acquisition record length or isolate a specific occurrence within an acquisition.
Easily transfer, document and analyze data on your PC.
Instrument Control
Utilizing the built-in Ethernet port, e*Scope web-based remote control allows you to a control TDS3000C Series oscilloscope from anywhere, using the Internet and your PC.
Work Where you Need to
The TDS3000C Series packs the power of a DPO in a compact design that is only 5.9 in. (149 mm) deep, freeing up valuable bench-top space. And when you need to move your oscilloscope to another lab, its portable 7 lbs (3.2 kg) design makes for easy transport.
If your work demands even more mobility, then the optional battery pack will give you up to three hours of operation without line power.
TDS3BATC provides you with up to three hours of portable battery operation. | |
Characteristics
TDS3000C Series Electrical Characteristics
|
TDS3012C |
TDS3014C |
TDS3032C |
TDS3034C |
TDS3052C |
TDS3054C |
Bandwidth |
100 MHz |
100 MHz |
300 MHz |
300 MHz |
500 MHz |
500 MHz |
Calculated Rise Time (typical) |
3.5 ns |
3.5 ns |
1.2 ns |
1.2 ns |
0.7 ns |
0.7 ns |
Input Channels |
2 |
4 |
2 |
4 |
2 |
4 |
External Trigger Input |
Included on all models |
Sample Rate on each channel |
1.25 GS/s |
1.25 GS/s |
2.5 GS/s |
2.5 GS/s |
5 GS/s |
5 GS/s |
Record Length |
10 k points |
Vertical Resolution |
9 bits |
Vertical Sensitivity, 1 MΩ |
1 mV/div to 10 V/div |
Vertical Sensitivity, 50 Ω |
1 mV/div to 1 V/div |
Input Coupling |
AC, DC, GND |
Input Impedance |
1 MΩ in parallel with 13 pF or 50 Ω |
DC Gain Accuracy |
+2% |
Maximum Input Voltage, 1 MΩ |
150 VRMS with peaks at < 400 V |
Maximum Input Voltage, 50 Ω |
5 VRMS with peaks at < 30 V |
Position Range |
+ 5 div |
Bandwidth Limit |
20 MHz |
20 MHz |
20 MHz, 150 MHz |
20 MHz, 150 MHz |
20 MHz, 150 MHz |
20 MHz, 150 MHz |
Time Base Range |
4 ns to 10 s |
4 ns to 10 s |
2 ns to 10 s |
2 ns to 10 s |
1 ns to 10 s |
1 ns to 10 s |
Time Base Accuracy |
+20 ppm over any 1 ms time interval |
Input/Output Interfaces |
Ethernet Port |
RJ-45 connector, supports 10Base-T LAN |
USB Port |
Front-panel USB 2.0 host port
Supports USB flash drive |
GPIB Port |
Full talk/listen modes, setting and measurements
(Optional with TDS3GV Communications Module) |
RS-232-C Port |
DB-9 male connector, full talk/listen modes; control of all modes, settings and measurements
Baud rates up to 38,400
(Optional with TDS3GV Communications Module) |
VGA Video Port |
DB-15 female connector, monitor output for direct display on large VGA-equipped monitors
(Optional with TDS3GV Communications Module) |
External Trigger Input |
BNC connector, input impedence > 1 MΩ in parallel with 17 pF; max input voltage is 150 VRMS |
Acquisition Modes |
DPO |
Captures and displays complex waveforms, random events and subtle patterns in actual signal behavior. DPOs provide 3 dimensions of signal information in real time: Amplitude, time and the distribution of amplitude over time. |
Peak Detect |
High frequency and random glitch capture. Captures glitches as narrow as 1 ns (typical) using acquisition hardware at all time base settings. |
WaveAlert® |
Monitors the incoming signals on all channels and alerts the user to any waveform that deviates from the normal waveform being acquired. |
Sample |
Sample data only |
Average |
Waveform averaged, selectable from 2 to 512 |
Envelope |
Min-max values acquired over one or more acquisitions |
Single Sequence |
Use the Single Sequence button to capture a single triggered acquisition sequence at a time |
Trigger System |
Main Trigger Modes |
Auto (supports Roll Mode for 40 ms/div and slower), Normal, Single Sequence |
B Trigger |
Trigger after time or events |
Trigger After Time Range |
13.2 ns to 50 s |
Trigger After Events Range |
1 to 9,999,999 events |
Trigger Types |
|
Edge |
Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject. |
Video |
Trigger on all lines or individual lines, odd/even or all fields on NTSC, PAL, SECAM |
Extended Video |
Trigger on specific lines in broadcast and non-broadcast (custom) standards and on analog HDTV formats (1080i, 1080p, 720p, 480p). Requires TDS3VID or TDS3SDI application module. |
Pulse Width
(or Glitch) |
Trigger on a pulse width <, >, =, ≠ to a selectable time limit ranging from 39.6 ns to 50 s |
Runt |
Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again |
Slew Rate |
Trigger on pulse edge rates that are either faster or slower than a set rate. Edges can be rising, falling or either. |
Pattern |
Specifies AND, OR, NAND, NOR when true or false for a specific time |
State |
Any logic state. Triggerable on rising or falling edge of a clock. Logic triggers can be used on combinations of 2 inputs (not 4). |
Comm |
Provides isolated pulse triggering required to perform DS1/DS3 telecommunications mask testing per ANSI T1.102 standard. Requires TDS3TMT application module. |
Alternate |
Sequentially uses each active channel as a trigger source |
Waveform Measurements |
Cursors |
Amplitude, Time |
Automatic Measurements |
Display any four measurements from any combination of waveforms. Or display all measurements with measurement snapshot feature. Measurements include Period, Frequency, +Width, -Width, Rise time, Fall time, +Duty cycle, -Duty cycle, +Overshoot, High, Low, Max, Min, Peak-to-peak, Amplitude, Mean, Cycle mean, RMS, Cycle RMS, Burst width, Delay, Phase, Area*1, Cycle Area*1 |
Measurement Statistics |
Mean, Min, Max, Standard deviation. Requires TDS3AAM application module. |
Thresholds |
User-definable thresholds for automatic measurements; settable in percent or voltage |
Gating |
Isolate a specific occurrence within an acquisition to take measurements, using either the screen or cursors |
Waveform Math |
Arithmetic |
Add, subtract, multiply, and divide waveforms |
FFT |
Spectral magnitude. Set FFT vertical scale to Linear RMS or dBV RMS, and FFT window to Rectangular, Hamming, Hanning, or Blackman-Harris. |
Advanced Math*1 |
Integrate, Differentiate, Define extensive algebraic expressions including analog waveforms, math functions, scalars, up to two user-adjustable variables and results of parametric measurements. For example: (Intg (Ch1-Mean(Ch1)) x 1.414 x VAR1).
Note: Requires TDS3AAM application module. |
Waveform Processing |
Autoset |
Single-button, automatic setup of all channels for vertical, horizontal and trigger systems, with undo autoset |
Deskew |
Channel-to-channel deskew +10 ns may be manually entered for better timing measurements and more accurate math waveforms |
Display Characteristics |
Display Type |
6.5 in. (165.1 mm) liquid crystal TFT color display |
Display Resolution |
640 horizontal x 480 vertical pixels (VGA) |
Interpolation |
Sin(x)/x |
Waveform styles |
Dots, vectors, variable persistence, infinite persistence |
Graticules |
Full, grid, cross-hair and frame. NTSC, PAL, SECAM, and vectorscope (100% and 75% color bars) with optional TDS3VID or TDS3SDI application modules |
Format |
YT, XY, and Gated XYZ (XY with Z-axis blanking available on 4-channel instruments only) |
Power Source |
AC line power |
|
Source voltage |
100 VRMS to 240 VRMS +10% |
Source frequency |
45 Hz to 440 Hz from 100 V to 120 V
45 Hz to 66 Hz from 120 V to 240 V |
Power consumption |
75 W maximum |
Battery power |
Requires TDS3BATC, rechargeable lithium ion battery pack |
Operating time, typical |
3 hours |
Environmental and Safety |
|
Operating |
Non-operating |
Temperature |
0 ºC to +50 ºC |
-40 ºC to +71 ºC |
Humidity |
Operating and Non-operating: up to 95% RH at or below +30 ºC
Operating and Non-operating: up to 45% RH +30 ºC up to +50 ºC |
Altitude |
To 3,000 m |
15,000 m |
Electromagnetic Compatibility |
Meets or exceeds EN61326 Class A, Annex D radiated and conducted emissions and immunity; EN6100-3-2 AC Powerline Harmonic Emissions; EN6100-3-3 Voltage Changes, Fluctuation, and Flicker; FCC 47 CFR, Part 15, Subpart B, Class A; Australian EMC framework. |
Safety |
UL61010B-1, CSA1010.1, IEC61010-1, EN61010-1 |
Physical Characteristics |
Instrument |
Dimensions |
mm |
in. |
Width |
375.0 |
14.8 |
Height |
176.0 |
6.9 |
Depth |
149.0 |
5.9 |
Weight |
kg |
lbs. |
Instrument only |
3.2 |
7.0 |
with accessories |
4.5 |
9.8 |
Instrument Shipping |
Package Dimensions |
mm |
in. |
Width |
502.0 |
19.8 |
Height |
375.0 |
14.8 |
Depth |
369.0 |
14.5 |
Rackmount (RM3000) |
Dimension |
mm |
in. |
Width |
484.0 |
19.0 |
Height |
178.0 |
7.0 |
Depth |
152.0 |
6.0 |
*1 Requires TDS3AAM application module.
Ordering Information
TDS3000C Series Digital Phosphor Oscilloscopes
TDS3012C |
100 MHz, 2 Channel, 1.25 GS/s |
TDS3014C |
100 MHz, 4 Channel, 1.25 GS/s |
TDS3032C |
300 MHz, 2 Channel, 2.5 GS/s |
TDS3034C |
300 MHz, 4 Channel, 2.5 GS/s |
TDS3052C |
500 MHz, 2 Channel, 5 GS/s |
TDS3054C |
500 MHz,.4 Channel, 5 GS/s |
Standard Accessories
One P6139A, 500 MHz, 10x passive probe per channel |
|
User Manual and Translated Front Panel Overlay |
Please specify preferred language option - see chart below |
Power Cord |
Please specify plug option - see chart below |
Accessory Tray |
|
Protective Front Cover |
|
OpenChoice® PC Communication Software |
Enables fast and easy communication between Windows PC and the TDS3000C series via LAN, GPIB, or RS-232. Transfer and save settings, waveforms, measurements and screen images. |
NI LabVIEW SignalExpress™ Tektronix Edition LE |
A fully interactive measurement software environment optimized for the TDS3000C series. Enables you to acquire, generate, analyze, compare, import and save measurement data and signals using intuitive drag-and-drop user interface that does not require any programming. Standard TDS3000C series support for acquiring, controlling, viewing and exporting your live signal data is permanently available through the software. A 30-day trial period of the full version provides additional signal processing, advance analysis, mixed signal, sweeping, limit testing and user-defined step capabilities. Order SIGEXPTE for permanent full version capability. |
Traceable Certificate of Calibration |
NIM/NIST |
Documentation CD |
|
3 Year Warranty |
Covering all labor and parts excluding probes and accessories |
Options
International Power Plugs Option |
Opt. A0 |
North America |
Opt. A1 |
Universal Euro |
Opt. A2 |
United Kingdom |
Opt. A3 |
Australia |
Opt. A5 |
Switzerland |
Opt. A6 |
Japan |
Opt. A10 |
China |
Opt. A11 |
India |
Opt. A99 |
No power cord |
Language Options Option |
Opt. L0 |
English |
Opt. L1 |
French |
Opt. L2 |
Italian |
Opt. L3 |
German |
Opt. L4 |
Spanish |
Opt. L5 |
Japanese |
Opt. L6 |
Portuguese |
Opt. L7 |
Simplified Chinese |
Opt. L8 |
Traditional Chinese |
Opt. L9 |
Korean |
Opt. L10 |
Russian |
Opt. L99 |
No manual |
Recommended Accessories
Accessories |
|
TDS3GV |
GPIB, VGA, RS-232 interface |
TDS3AAM |
Advanced Analysis Module. Adds extended math capability, arbitrary math expressions, measurement statistics and additional automated measurements. |
TDS3LIM |
Limit Testing Module. Adds custom waveform limit testing capabilities. |
TDS3TMT |
Telecom Mask Testing Module. Adds pass/fail compliance of ITU-T G.703 and ANSI T1.102 standards, custom mask testing and more. |
TDS3VID |
Extended Video Analysis Module. Adds video quickmenu, autoset, hold, line count trigger, video picture mode, vectorscope*2 mode, HDTV format trigger graticules and more. |
TDS3SDI |
Serial/Digital Video Module. Adds 601 serial digital video to analog video conversion, video picture, vectorscope*2, and analog HDTV triggering capabilities and more. |
TDS3BATC |
Lithium ion battery pack for up to 3 hours continuous operation without line power |
TDS3CHG |
Fast charger for battery pack |
AC3000 |
Soft case for carrying instrument |
HCTEK4321 |
Hard plastic case for carrying instrument (requires AC3000) |
RM3000 |
Rackmount kit |
SIGEXPTE |
NI LabVIEW SignalExpress™ Tektronix Edition Software full version |
Service Manual |
English only (071-2507-00) |
TNGTDS01 |
Extensive instructions and step-by-step lab exercises provide education about the operation of TDS3000C Series Oscilloscopes. Kit includes self-paced CD-ROM based manual and signal source board. Optional hard copy manual available for order separately. |
Recommended Probes
Probes |
P6243 |
1 GHz, <1 pF input C 10X active probe |
P5205 |
1.3 kV, 100 MHz high voltage differential probe |
P5210 |
5.6 kV, 50 MHz high voltage differential probe |
P5100 |
2.5 kV, 100X high voltage passive probe |
TCP202 |
50 MHz, 15 A AC/DC current probe |
TCP303*3 |
15 MHz, 150 A current probe |
TCP305*3 |
50 MHz, 50 A current probe |
TCP312*3 |
100 MHz, 30 A current probe |
TCPA300 |
100 MHz probe amplifier |
TCP404XL*4 |
2 MHz, 500 A current probe |
TCPA400 |
50 MHz probe amplifier |
ADA400A |
100X, 10X, 1X, 0.1X high gain differential amplifier |
Service Options
Options |
Available at time of purchase |
Opt. CA1 |
Provides a single calibration event or coverage for the designated calibration interval, whichever comes first |
Opt. C3 |
Calibration Service - 3 years |
Opt. C5 |
Calibration Service - 5 years |
Opt. D1 |
Calibration Data Report |
Opt. D3 |
Calibration Data Report - 3 years (with Option C3) |
Opt. D5 |
Calibration Data Report - 5 years (with Option C5) |
Opt. R5 |
Repair Service - 5 year |
Available after purchase |
TDS30xxC-CA1 |
Provides a single calibration event or coverage for the designated calibration interval, whichever comes first |
TDS30xxC-R1PW |
Repair service coverage 1 year post warranty |
TDS30xxC-R2PW |
Repair service coverage 2 years post warranty |
TDS30xxC-R5DW |
Repair service coverage 5 years (includes product warranty period); 5 year period starts at time of customer instrument purchase |
*2 Vectorscope does not support composite video.
*3 Requires TCPA300 probe amplifier.
*4 Requires TCPA400 probe amplifier. | |
|