Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times) | 3288 | 3288-20 |
---|
DC current | 100.0/ 1000 A, Basic accuracy: ±1.5 % rdg. ±5 dgt. |
---|
AC current | 100.0/ 1000 A, (10 Hz to 500 Hz, Average rectified), Basic accuracy: ±1.5 % rdg. ±5 dgt. | 100.0/ 1000 A, (10 Hz to 500 Hz, True RMS), Basic accuracy: ±1.5 % rdg. ±5 dgt. |
---|
DC voltage | 419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.3 % rdg. ±4 dgt. |
---|
AC voltage | 4.199 V to 600 V, 4 ranges, Basic accuracy: ±2.3 % rdg. ±8 dgt. (30 to 500 Hz, Average rectified) | 4.199 V to 600 V, 4 ranges, Basic accuracy: ±2.3 % rdg. ±8 dgt. (30 to 500 Hz, True RMS) |
---|
Resistance | 419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt. |
---|
Crest factor | N/A | 3 or less (2 at 1000 A range, 1.5 at Voltage) |
---|
Other functions | Continuity: (50 Ω ±40 Ω) or less buzzer sounds, Data hold, Auto power save, Auto zero (DC A) |
---|
Display | LCD, max. 4199 dgt., Display refresh rate: 2.5 times/s |
---|
Power supply | Coin type lithium battery (CR2032) ×1, Continuous use 60 hours | Coin type lithium battery (CR2032) ×1, Continuous use 35 hours |
---|
Core jaw dia. | φ 35 mm (1.38 in) |
---|
Dimensions and mass | 57 mm (2.24 in) W × 180 mm (7.09 in) H × 16 mm (0.63 in) D, 150 g (5.3 oz) |
---|
Accessories | Instruction manual ×1, Test Lead L9208 ×1, Carrying Case 9398 ×1 |
---|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
Hioki clamp on meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The 3288 and 3288-10 are AC/DC current and voltage clamp meters that also measures continuity and resistance, featuring a double jaw lever and slim profile for easy access to crowded wires.
• Model 3288-20: True RMS • Use the 3288 for high current measurements such as UPS emergency batteries and train motors • Voltage, resistance, and continuity check functions
|
|
|
|
|
|
|