Model | AFC-500W | AFC-1KW | AFC-11003 | AFC-11005 | AFC-11008 | AFC-11010 | AFC-11015 | AFC-11020 | AFC-11030 | Capacity (kVA) | 0.5 | 1 | 3 | 5 | 8 | 10 | 15 | 20 | 30 | Circuit Type | Transistor amplifier type | IGBT/PWM type | Input | Phase | Single phase | Wave | SINE WAVE | Voltage | 220V | Voltage range | 220V¡À15% | Frequency range | 50Hz¡À3Hz »ò 60Hz¡À3Hz | Power factor | 0.85 | Output | Phase | Single phase | Wave | SINE WAVE | Voltage | Low | 0~150V£¨L-N£© | 5V-150V£¨L-N£© | High | 0~300V£¨L-N£© | 10V-300V£¨L-N£© | Frequency | 47~63Hz Adjustable£¬50Hz£¬60Hz£» 2F£¬4F£¬400Hz£¨Option£© | Frequency regulation | ¡Ü0.01% | Max. current | High (A) | 2.1 | 4.2 | 12.5 | 20.8 | 33.3 | 41.7 | 62.5 | 83.3 | 125.0 | Low (A) | 4.2 | 8.4 | 25 | 41.7 | 66.7 | 83.3 | 125.0 | 166.7 | 250.0 | System | Line regulation | ¡À0.2% | £¼1% | Load regulation | ¡À0.2% | ¡À1% (linear load) | Total harmonic distortion (THD) | 0.2% | 2% (linear load) | Efficiency | ¨R70% | ¨R90% | Response time | ¨Q5¦Ìs | ¨Q2ms | Wave factor | 1.4:1 | 3:1 | Protection device | Input no-fuse breaker, output no-fuse breaker, electronic circuit instant trip for over/low voltage, over current, over load, over temperature and short circuit protection and alarm system ¡¡ | Input no-fuse breaker, electronic circuit instant trip for over/low voltage, over current, over load, over temperature and short circuit protection and alarm system
¡¡ | Indicator | Display | LED | Voltage | Show range: 0~600V, analytic degree: 0.1V, accurate degree: 0.15%FS+4COUNT | Current | Show range: 0~700A, analytic degree: 0.01A(<100A)/0.1A(¡Ý100A), accurate degree: 0.2%FS+4COUNT | Power | 4 COUNT digitally watt meter analytic degree: 1W | Show range: 3kW~75kW, analytic degree: 0.01kW(<10kW)/0.1kW(¡Ý10kW), accurate degree: 0.3%FS+4COUNT | Frequency | Show range: 0~999.9Hz, analytic degree: 0.1Hz, accurate degree: 0.1% | Environment | Insulation resistance | DC500V ¨R 20M¦¸ | Withstand voltage insulation | AC 1800V 5mA/1Min | Cooling system | Fan cooling | Temperature | 0¡æ~40¡æ | Humidity | 0~90% (Non-condensing) | Altitude | ¨Q 1500m | Case No. | ¢Ù | ¡¡ ¢Ú | ¡¡¢Û | ¡¡¢Ü | Weight(kg) | 44 | 89 | 73 | 89 | 200 | 210 | 240 | 280 | 330 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
One key for shutdown when fault.
Quick response speed. Response time ¡Ü2ms.
High accurate measurement for parameter: Voltage, 0.15%FS+4COUNT; Current, 0.2%FS+4COUNT; Frequency, 0.1%; Power, 0.3%FS+4COUNT.
Output voltage: 5~300V continuous adjustable. Quick & convenient 3 scales of preset voltage for high and low voltage simulation: High: +10%~+25% of preset voltage; Medium: preset voltage; Low: -10%~-30% of preset voltage.
Pure output sine-wave. (Please see specification table).
Well protection and fault alarm function: Input no-fuse breaker; electronic circuit instant trip for over voltage, over current, over load, over temperature and short circuit protection and alarm system.
Power module design patent.
|
|
|
|
|
|
|