|
|
|
|
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)DC Current | 600.0 A/2000 A, Basic accuracy: ±1.3% rdg. ±3 dgt. |
---|
AC Current | 600.0 A/2000 A, (10 Hz to 1 kHz, True RMS) Basic accuracy: ±1.3% rdg. ±3 dgt. |
---|
DC Voltage | 600.0 mV to 1500 V, 5 ranges, Basic accuracy: ±0.5% rdg. ±3 dgt. |
---|
AC Voltage | 6.000 V to 1000 V, 4 ranges, (15 Hz to 1 kHz, True RMS) Basic accuracy: ±0.9% rdg. ±3 dgt. |
---|
DC+AC Current | 600.0 A/2000 A, (10 Hz to 1 kHz, True RMS) Basic accuracy: ±1.3% rdg. ±13 dgt. |
---|
DC+AC Voltage | 6.000 V to 1000 V, 4 ranges, Basic accuracy: ±1.0% rdg. ±7 dgt. |
---|
Resistance | 600.0 Ω to 600.0 kΩ, 4 ranges, Basic accuracy: ±0.7% rdg. ±5 dgt. |
---|
Electrostatic capacity | 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±5 dgt. |
---|
Frequency | 9.999 Hz to 999.9 Hz, Basic accuracy: ±0.1% rdg. ±1 dgt. |
---|
Continuity check | Continuity threshold [ON]: 25Ω±10 Ω (Buzzor sound, red LED)Continuity threshold [OFF]: 245 Ω±10 Ω, Response time: 0.5 ms or more |
---|
Diode | Open terminal voltage: DC2.0 V or less, Measurement current: 200 μA, forward connection: 0.15 V to 1.8 V |
---|
Temperature (K) | -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C |
---|
Voltage detection | Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz |
---|
DC Power | Display range switching: 0.000 VA to 3400 kVA, Accuracy: ±2.0% rdg. ±20 dgt. |
---|
Crest factor | [600.0 A range] 500.0 A or less: 3; greater than 500.0 A and less than or equal to 600.0 A: 2.5 [2000 A range] 1000 A or less: 2.84; greater than 1000 A and less than or equal to 2000 A: 1.42 |
---|
Other functions | Automatic AC/DC detection, Plus/Minus judgement function of DC A, DC V, Max/Min/Average/PEAK MAX/ PEAK MIN value display, Filter function, Display value hold, Auto hold, Back light, Auto-power save, Buzzer sounds |
---|
Display | Update rate: 5 times/s (excluding electrostatic capacity, frequency, and temperature) |
---|
Power supply | LR03 Alkaline battery ×2, Approx. 45 hours (Backlight OFF) |
---|
Core jaw diameter | 92 mm (3.62 in) W×18 mm (0.71 in) D, φ55 mm (2.17 in) |
---|
Dimensions and mass | 65 mm (2.56 in) W×250 mm (9.84 in) H×35 mm (1.38 in) D mm, 530 g (18.7 oz) |
---|
Accessories | TEST LEAD L9207-10, CARRYING CASE C0203, LR03 Alkaline battery ×2, Instruction Manual
|
---|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
Hioki clamp on meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. Model CM4373 is a 2000A True RMS clamp meter that features stronger jaws, broader -25℃ to 65℃ operating temperature range and IP54 dustproof and waterproof enclosure to enable professionals to work quickly in tough situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 1700 V is ideal for the clamp maintenance inspections of electrical and solar power equipment.
• Multiple measurement functions such as current, voltage, resistance, ferequency, and voltage detection • Simultancously measure inrush current in RMS and crest values • Damage-resistant jaws (current sensor) provide even more years of reliable use. • Expanded -25 °C to 65 °C operating temperature range • IP54 dustproof and waterproof enclosure *Jaws (current sensor portion): IP50 • Automatic AC/DC function helps boost work efficiency • Remain alert to hazards with a red backlight and beeping tone • Measure DC voltages of up to 1700 V
|
|
|
|
|
|
|